- Product
- Infinity¿ sampling device, Cytology Brush, United States Endoscopy Group, Inc., 5976 Heisley Road, Mentor, OH 44060 The Infinity sampling device is a disposable cytology brush used to retrieve cytological cell samples in the gastrointestinal tract.
- Firm
- US Endoscopy Group Inc
- Event
- Event 63047
- Initiated
- December 22, 2011
-
- Product
- Tibial Punch Tower Assembly. Non-Sterile. CAT NO. 8000-1089. Howmedica Osteonics Corp., 59 Route 17, Allendale, NJ 07401. During primary Scorpio TKA procedures, the Scorpio Tibial Punch Tower (8000-1089) is used in conjunction with Scorpio Tibial Keel Punches (3760-0305/-0709/-1113 and 3761-0305/-0709/-1113) and Tibial Templates (3750-0003/-0005/-0007/-0009/-0013) to prepare the tibia for baseplate implantation. Per the surgical protocol for Duracon and Scorpio Total Knee Systems with Xcelerate Instrumentation (LSPK31 03/03), tibial templates are used to determine the appropriate coverage of the tibial plateau. Once a template size is selected, the device is secured to the plateau with fixation pins, and the tibial punch tower is assembled by placing the tower onto the two small locating pins on the tibial template. A keel punch is then selected, assembled into the channel of the tower, and impacted with a mallet. Depending on the intended implant size, several keel punches of increasing size may be utilized to incrementally enlarge the cavity. Each keel punch is advanced until it fully seats on the tibial template. Tibial preparation is considered complete when the final keel punch fully seats on the tibial template.
- Firm
- Stryker Howmedica Osteonics Corp.
- Event
- Event 62365
- Initiated
- December 22, 2011
-
- Product
- GE Healthcare innova 3100-IQ, Mobile X-ray system The innova systems are indicated for use in generating fluoroscopic images of human anatomy for vascular angiography, diagnostic and interventional procedures, and optionally , rotational angiography procedures. They are also indicated for generating fluoroscopic images of human anatomy for cardiology, diagnostic, and interventional procedures.
- Firm
- GE Healthcare, LLC
- Event
- Event 63027
- Initiated
- December 20, 2011
-
- Product
- GE Healthcare innova 3100, Mobile X-ray system. The innova systems are indicated for use in generating fluoroscopic images of human anatomy for vascular angiography, diagnostic and interventional procedures, and optionally , rotational angiography procedures. They are also indicated for generating fluoroscopic images of human anatomy for cardiology, diagnostic, and interventional procedures.
- Firm
- GE Healthcare, LLC
- Event
- Event 63027
- Initiated
- December 20, 2011
-
- Product
- GE Healthcare innova 3131-IQ Mobile X-ray system. The innova systems are indicated for use in generating fluoroscopic images of human anatomy for vascular angiography, diagnostic and interventional procedures, and optionally , rotational angiography procedures. They are also indicated for generating fluoroscopic images of human anatomy for cardiology, diagnostic, and interventional procedures.
- Firm
- GE Healthcare, LLC
- Event
- Event 63027
- Initiated
- December 20, 2011
-
- Product
- GE Healthcare Innova 2100 IQ, Innova 3100 IQ, Innova 4100 IQ, Innova 2121 IQ, Innova 3131 IQ , Innova 3100, Innova 4100. For use in generating fluoroscopic images of human anatomy for diagnostic and interventional procedures.
- Firm
- GE Healthcare, LLC
- Event
- Event 65029
- Initiated
- December 20, 2011
-
- Product
- Telluride Percutaneous Rod Inserter Long, Model #7706-1904. The Inserter is a reusable device provided within an aluminum sterilization case along with other orthopedic manual surgical instruments. The case consists of three trays of instruments, and the middle tray contains a quantity of two Inserters. The Inserter is for use as part of a Telluride System pedicle screw procedure.
- Firm
- Biomet Spine, LLC
- Event
- Event 70376
- Initiated
- December 19, 2011
-
- Product
- Eon (Model 3716) IPG is a dual channel; 8-contact receiver designed to be connected to 4, 8, or 16 electrode leads or a lead extension. Product Usage: The Eon and Eon Mini Neurostimulation Systems are indicated as an aid in the management of chronic intractable pain of the trunk and/or limbs including unilateral or bilateral pain associated with the following: failed back surgery syndrome, intractable low back and leg pain.
- Firm
- Advanced Neuromodulation Systems Inc.
- Event
- Event 61171
- Initiated
- December 19, 2011
-
- Product
- The Eon Mini Neurostimulation (IPG) System (Model 3788) is a 16-channel, rechargeable, multi-program system that allows the connection of one or two leads with 4, 8, and 16 electrode leads. Product Usage: The Eon and Eon Mini Neurostimulation Systems are indicated as an aid in the management of chronic intractable pain of the trunk and/or limbs including unilateral or bilateral pain associated with the following: failed back surgery syndrome, intractable low back and leg pain.
- Firm
- Advanced Neuromodulation Systems Inc.
- Event
- Event 61171
- Initiated
- December 19, 2011
-
- Product
- Eon Mini Neurostimulation (IPG) System (Model 3788); The product is indicated as an aid in the management of chronic intractable pain of the trunk and/or limbs including unilateral or bilateral pain associated with the following: failed back surgery syndrome, intractable low back and leg pain.
- Firm
- Advanced Neuromodulation Systems Inc.
- Event
- Event 61151
- Initiated
- December 19, 2011
-
- Product
- Actra-SX 500 Capsules, Maximum Strength, Energizer, 500 mg, 5 count package, Body Basics, Canoga Park, CA
- Firm
- Body Basics Inc
- Event
- Event 62836
- Initiated
- December 19, 2011
-
- Product
- Synchron Systems Synchron Calibrator Multi Calibrator Diskettes, Part Number 442600. The SYNCHRON MULTI-CALIBRATOR, used in conjunction with SYNCHRON reagents, is intended for use on SYNCHRON Systems for the calibration of Albumin, Blood Urea Nitrogen (Urea), Calcium, Cholesterol, Glucose, Inorganic Phosphorus, Lactate,Magnesium, Total Protein, Triglycerides, and Uric Acid.
- Firm
- Beckman Coulter Inc.
- Event
- Event 63130
- Initiated
- December 15, 2011
-
- Product
- UniCel DxH Slidemaker Stainer Instrument System, PN 775222. The DxH Slidemaker Stainer is a fully automated slide preparation and staining device that aspirates a whole blood-sample, smears a blood film on a clean microscope slide, and delivers a variety of fixatives, stains, buffers, and rinse solutions to that blood smear. The DxH Slidemaker Stainer allows for adaptation of the smear appearance and stain methodology according to user preferences. Blood smears produced by the Slidemaker portion of the DxH Slidemaker Stainer are moved to baskets for transfer to the Stainer portion by a robot arm. Microscopic examination of the stained blood smears can be used to help determine the hematologic status of a patient. A stained blood film: " Allows for the differentiation of white blood cells " Facilitates the characterization of red blood cells and platelets " Aids in the identification of blood components and cellular abnormalities The optional floor stand has four drawers for storing the reagent and waste containers currently in use in the DxH Slidemaker Stainer.
- Firm
- Beckman Coulter Inc.
- Event
- Event 62755
- Initiated
- December 13, 2011
-
- Product
- UniCel DxH Slidemaker Stainer Stainer Floor Cabinet, PN A96152. The DxH Slidemaker Stainer is a fully automated slide preparation and staining device that aspirates a whole blood-sample, smears a blood film on a clean microscope slide, and delivers a variety of fixatives, stains, buffers, and rinse solutions to that blood smear. The DxH Slidemaker Stainer allows for adaptation of the smear appearance and stain methodology according to user preferences. Blood smears produced by the Slidemaker portion of the DxH Slidemaker Stainer are moved to baskets for transfer to the Stainer portion by a robot arm. Microscopic examination of the stained blood smears can be used to help determine the hematologic status of a patient. A stained blood film: " Allows for the differentiation of white blood cells " Facilitates the characterization of red blood cells and platelets " Aids in the identification of blood components and cellular abnormalities The optional floor stand has four drawers for storing the reagent and waste containers currently in use in the DxH Slidemaker Stainer.
- Firm
- Beckman Coulter Inc.
- Event
- Event 62755
- Initiated
- December 13, 2011
-
- Product
- Vector TAS Modular Driver, a manual driver for Vector TAS dental screws.
- Firm
- Ormco/Sybronendo
- Event
- Event 63412
- Initiated
- December 12, 2011
-
- Product
- Progressive Medical PMI Endoscopic Dissector with Kittner Tip (5mm x 40cm), Reorder Number: PMILK40, Product Sterile in Unopened/Undamaged pouch, Cotton Tip - X-Ray Detectable, 1 Pc/Pouch, 10 Pouches/Box, 20 boxes/case. Exclusively Distributed in the U.S. Market by: Progressive Medical, Inc., St. Louis, MO, Made in China. The product is used for pushing tissue from the incision or wound during medical procedures. Per the IFU, the indications for use are for gynecological laparoscopy, laparoscopic cholecystectomy, and other laparoscopic procedures.
- Firm
- Progressive Medical Inc
- Event
- Event 63445
- Initiated
- December 09, 2011
-
- Product
- PrepStain Upgrade Kit: 1.3.0.3/1.2 DiTi Cone. The PrepStain System is a liquid-based thin layer cell preparation process. The PrepStain System produces SurePath Slides that are intended for use in the screening and detection of cervical cancer, pre-cancerous lesions, atypical cells and all other cytologic categories as defined by The Bethesda System for Reporting Cervical/Vaginal Cytology Diagnoses. The 1.2 DiTi is the tip on the PrepStain to which a pipette tip attaches and dispenses patient samples onto a glass microscope slide.
- Firm
- Tripath Imaging, Inc.
- Event
- Event 62117
- Initiated
- December 08, 2011
-
- Product
- PrepStain PM Kit, T-AG (Catalog 490588); PrepStain PM Kit Europe (Catalog 490671); PrepStain Prep Only PM Kit, T-AG (Catalog 490954); PrepStain PM Kit XLP, T-US-II (Catalog 490424); PrepStain Prep PM Kit XLP T-US-II (Catalog 491118); PrepStain Prep Only PM Kit XLP, T-US-II (490423); PrepStain Prep Only PM Kit, T-US (Catalog 490429); PrepStain PM Kit, T-US (Catalog 490626); PrepStain PM Kit Europe, T-US (Catalog 490428). The PrepStain System is a liquid-based thin layer cell preparation process. The PrepStain System produces SurePath Slides that are intended for use in the screening and detection of cervical cancer, pre-cancerous lesions, atypical cells and all other cytologic categories as defined by The Bethesda System for Reporting Cervical/Vaginal Cytology Diagnoses. The 1.2 DiTi is the tip on the PrepStain to which a pipette tip attaches and dispenses patient samples onto a glass microscope slide.
- Firm
- Tripath Imaging, Inc.
- Event
- Event 62117
- Initiated
- December 08, 2011
-
- Product
- PrepStain Slide Processor. The PrepStain System is a liquid-based thin layer cell preparation process. The PrepStain System produces SurePath Slides that are intended for use in the screening and detection of cervical cancer, pre-cancerous lesions, atypical cells and all other cytologic categories as defined by The Bethesda System for Reporting Cervical/Vaginal Cytology Diagnoses. The 1.2 DiTi is the tip on the PrepStain to which a pipette tip attaches and dispenses patient samples onto a glass microscope slide.
- Firm
- Tripath Imaging, Inc.
- Event
- Event 62117
- Initiated
- December 08, 2011
-
- Product
- PrepStain Kit: 1.2 DiTi Cone. The PrepStain System is a liquid-based thin layer cell preparation process. The PrepStain System produces SurePath Slides that are intended for use in the screening and detection of cervical cancer, pre-cancerous lesions, atypical cells and all other cytologic categories as defined by The Bethesda System for Reporting Cervical/Vaginal Cytology Diagnoses. The 1.2 DiTi is the tip on the PrepStain to which a pipette tip attaches and dispenses patient samples onto a glass microscope slide.
- Firm
- Tripath Imaging, Inc.
- Event
- Event 62117
- Initiated
- December 08, 2011
-
- Product
- Sunquest Laboratory Versions 6.4 and later using Microbiology Result Entry
- Firm
- Sunquest Information Systems, Inc.
- Event
- Event 62708
- Initiated
- December 05, 2011
-
- Product
- Argatroban Injection 50 mg per 50ml (1 mg per ml) For Intravenous Infusion Only, a) Single Use Vial (NDC 42367-203-07), b) 10 Single Use Vials(NDC 42367-203-84), Rx Only, Manufactured by: Cipla LTD, India, Manufactured for: Eagle Pharmaceuticals, Inc. Woodcliff Lake, NJ 07677 USA, Marketed by: The Medicines Company, Parsippany, NJ 07054 USA
- Firm
- Eagle Pharmaceuticals Inc.
- Event
- Event 61108
- Initiated
- December 02, 2011
-
- Product
- TSX-IOI: AQUILION 32/64; System, X-Ray, Tomography, Computed. Designed to produce cross-sectional images of a human body.
- Firm
- Toshiba American Medical Systems Inc
- Event
- Event 64667
- Initiated
- November 30, 2011