Failure mode assignments

Deterministic labels derived from preserved recall-reason text.

Indexed record set

89,789 assignments

Page 30 of 3592

Mode Product Rule Evidence excerpt
Device software or design Centricity Cardio Imaging 5.0 is a software only Picture Archiving and Communication System (PACS). Product Usage: It will be sold as a software only device to operate on general purpose computing hardware. Centricity Cardio Imaging receives medical images and other information from various data sources. Information can be stored, communicated, processed and displayed within the system or across computer networks at distributed locations. Centricity Cardio Imaging is intended to assist trained professionals in the viewing, analysis and diagnostic interpretation of images and other information for the diagnosis and treatment of cardiac and vascular disease. These trained professionals include but are not limited to physicians, cardiologists, radiologists, nurses, medical technicians and assistants. Centricity Cardio Imaging is not intended for use in the patient vicinity. reason.device_software_design · v1.0.0 software of the Centricity Cardio Imaging product, version 5.0 SP1. Multiple studies may
Device software or design ARIA Radiation Oncology, versions 10, 11 , 13.0 and 13.5 with Clinical Assessment License. Model number HIT Product Usage: ARIA Radiation Oncology is a radiation treatment plan and image management application. reason.device_software_design · v1.0.0 anomaly was identified with the ARIA for Radiation Oncology software
Device software or design software for Syngo Dynamics a Picture Archiving and Communication System (PACS) intended for acceptance, transfer, display, storage, archive and manipulation of digital medical images, including quantification and report generation. Syngo Dynamics is not intended to be used for reading of mammography images. reason.device_software_design · v1.0.0 software update that addresses an issue
Device software or design SOMATOM Definition AS, intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from either the same axial plane taken at different angles or spiral planes taken at different angles. reason.device_software_design · v1.0.0 software bug
Device software or design RetCam 3, RetCam Portable and RetCam Shuttle; manufactured by Clarity Medical Systems, Inc.; Pleasanton, CA 94588. General ophthalmic imaging including retinal, corneal and external imaging. reason.device_software_design · v1.0.0 Software anomaly
Device software or design COMPASS, Model No. SW Version 3.1, catalogue number CS10-100 (medical Linear accelerator) radiological reason.device_software_design · v1.0.0 Error in the software
Device software or design Intellispace Portal (ISP) Philips Medical Systems (Cleveland), Inc., IntelliSpace Portal (ISP) is a multimodality (CT, NM, and MR) thin-client applications server that delivers full diagnostic viewing and clinical applications to the enterprise. IntelliSpace Portal (ISP) is a medical software system that allows multiple users to remotely access IntelliSpace Workspace Portal (ISP) from compatible computers on a network. The system allows networking, selection, processing and filming of multimodality DICOM images. Both the client and server software are only for use with off the shelf hardware technology that meets defined minimum specifications. trained physicians may use the images as a basis for diagnosis upon ensuring that monitor quality, ambient light conditions and image compression ratios are consistent with clinical application. reason.device_software_design · v1.0.0 problem using the IntelliSpace Portal with software
Device software or design Spacelabs Healthcare G2 Clinical Access Mislabeled CDs for PN: 063-1829-11 Rev A and Update Kit, PN: 040-1565-10. Used for installing ICS G2 Clinical Access software onto hospital personal computers. reason.device_software_design · v1.0.0 Software CD because the programs installed on the Clinical Access CD are incorrect and it will prevent
Device software or design AU5800 Clinical Chemistry Analyzer with Automation Ready Connection (All Software Versions), Model Numbers AU5811, AU5821, AU5831 and AU5841. This system is for in vitro diagnostic use only. reason.device_software_design · v1.0.0 software error
Device software or design Omnicycle Elite; US Importer and Distributor: Accelerated Care Plus, Reno NV. Manufactured by Medica Medizintechnik GmbH, Hochdorf, Germany. The product is indicated for powered exercise equipment intended for medical purposes. reason.device_software_design · v1.0.0 anomaly in the firmware
Device software or design IntelliVue MX40 Wearable Patient Monitor in use with the Philips IntelliVue Information Center iX (PIIC iX); 865350, 865351, 865352 reason.device_software_design · v1.0.0 software revisions B.00 or B.01 may
Device software or design Stryker TPS Universal Driver REF 5100- 99 Rx , The Stryker Total Performance System (TPS) is intended for use in the cutting, drilling, reaming, decorticating and smoothing of bone and other bone related tissues for a variety of applications such as ENT, dental orthopedic, maxillofacial, spinal, and plastic surgery. The instruments are also used in the placement of screws, wires, pins, and other fixation devices. reason.device_software_design · v1.0.0 software. Handpieces that have been programmed with the incorrect
Device software or design VITROS 5,1 FS Chemistry System, Catalog Number/Product Code 6801375, Unique Device Identifier No. 10758750001132, and VITROS 5,1 FS Chemistry System Refurbished, Catalog Number/Product Code 6801890, Unique Device Identifier No. 10758750001644, IVD --- Ortho Clinical Diagnostics Inc. The VITROS 5,1 FS Chemistry System with enGEN Laboratory Automation System is intended for use in the in vitro quantitative measurement of a variety of analytes of clinical interest, using both VITROS Chemistry Products Slides (colorimetric endpoint, rate, ion-selective electrode, and immunorate methods) and VITROS Chemistry Products MicroTip liquid reagents (spectrophotometric and spectrophotometric immunoassay methods.) reason.device_software_design · v1.0.0 Software anomaly
Device software or design Transonic Flow Probe, 3 mm, Catalog Number HQC3MP -- Product Usage: to measure flow intra-operatively. reason.device_software_design · v1.0.0 Software defect
Device software or design GEMINI TF Base CT/PET System. The Philips GEMINI PET/CT Imaging Systems are a family of integrated diagnostic X-ray Computed Tomography (CT) and Positron Emission Tomography (PET) systems suitable for a wide range of diagnostic applications. reason.device_software_design · v1.0.0 software defects in the Tumor LOC software application that may potentially result in
Device software or design bioMerieux Vitek 2 Systems Software version 6.01 software, used with the VITEK 2 automated system. Kit, UPDT V2S 6.01 ES. Part number: 414561. The product is used with the VITEK 2 automated system which consists of instruments, software and reagent cards designed for the identification and antimicrobial susceptibility testing of bacteria and yeast. reason.device_software_design · v1.0.0 issue has been identified for customers using software
Device software or design Transonic Flow Probe, 2 mm, Catalog Number HQC2FMC Product Usage: to measure flow intra-operatively. reason.device_software_design · v1.0.0 Software defect
Device software or design GEMINI TF 16 Slice CT/PET System. The Philips GEMINI PET/CT Imaging Systems are a family of integrated diagnostic X-ray Computed Tomography (CT) and Positron Emission Tomography (PET) systems suitable for a wide range of diagnostic applications. reason.device_software_design · v1.0.0 software defects in the Tumor LOC software application that may potentially result in
Device software or design Volcano s5/s5i/CORE Intravascular Ultrasound Systems with software versions 3.3 and 3.4 (with and without iFR Scout Technology) and v.3.4 software kits; Model s5. Radiology: The Volcano s5/s5i and CORE Series Intravascular Imaging and Pressure System is used for the qualitative and quantitative evaluation of vascular morphology in the coronary arteries and vessels of the peripheral vasculature reason.device_software_design · v1.0.0 software issue
Device software or design ARTISTE, ONCOR Avantgarde, ONCOR Impression Plus, ONCOR Expression, PRIMUS, PRIMUS Plus, Syngo RT Therapist; therapeutic treatment of cancer Product Usage: The intended use of the SIEMENS branded ARTISTE and ONCOR family of linear accelerator systems is to deliver X-Ray photon and electron radiation for the therapeutic treatment of cancer. PRIMUSTM family of linear accelerator systems is to deliver x-ray radiation for therapeutic treatment of cancer. Syngo RT Therapist is a software application whose indication for use includes the viewing, processing, filming, and archiving of medical images. It also permits patient data management, patient selection/setup, patient positioning verification, treatment planning, treatment delivery/verification, and treatment recording. reason.device_software_design · v1.0.0 software fix has been released to prevent
Device software or design Ingenuity TF PET/CT. Diagnostic imaging system that combines Positron Emission Tomography (PET) and X-ray Computed Tomography (CT) systems. reason.device_software_design · v1.0.0 software version 4.0.60605.0 that if they were to re-occur, could cause
Device software or design Aquarius iNtuition Client Viewer. Findings Workflow module, RECIST 1.1: Picture Archiving and Communications System; Findings Workflow Modules 4.4.11.82.6784, 4.4.11.116.7134, 4.4.11.144.7589. A fully-configured iNtuition system is capable of various image processing and visualization functions, including basic features and advanced post processing modules. The system can be configured as a server with some, all, or none of its optional features disabled. The intended use of the device is to provide solutions to various medical image-analysis and viewing problems, which come about as modalities generate more and more images. It also supports image distribution over networks, and is DICOM compliant. reason.device_software_design · v1.0.0 Software anomaly
Device software or design VITROS 4600 Chemistry System, Software Version 3.2 & Below. Automates pre-analytical and post-analytical sample and data management for in vitro diagnostic use. reason.device_software_design · v1.0.0 Software anomaly
Device software or design Ref: VP1600 HD Still Capture System ConMed Linvatec . Captures, stores and transfers images generated by a medical endoscopic camera system during surgical procedures. reason.device_software_design · v1.0.0 anomaly between the software
Device software or design Volcano s5/s5i/CORE Intravascular Ultrasound Systems software versions 3.3 and 3.4 (with and without iFR Scout Technology) and v.3.4 software kits; Model CORE Radiology: The Volcano s5/s5i and CORE Series Intravascular Imaging and Pressure System is used for the qualitative and quantitative evaluation of vascular morphology in the coronary arteries and vessels of the peripheral vasculature reason.device_software_design · v1.0.0 software issue