Skip to content
Recall Observatory FDA recall evidence

Device product

Praxair Vantage Grab n Go - Gas Cylinder pressure regulator Catalog Number: OX-M-AEGNGVNTG Usage: Regulator reduces pressure in oxygen-containing cylinder.

Z-0525-2013

November 16, 2012

Class I

Product summary

Firm
Praxair Inc.
Event
Event 63729
Status
Terminated
Classification
Class I
Quantity
320,451 units (255,690 US ; 55,884 Canada; 8877 OUS)
Official record key
device-enforcement:Z-0525-2013

Official wording

Reason: Isolated incidents of ignition inside Grab n' Go cylinders that had been knocked over or otherwise subject to significant physical impact.

Code information: OX M-AEGNGVNTG (US and Canada) and WESPRX-9500 (Global) Cyclinders in service since Jan 2009. Units with a "T" decal (T-teflon) on the fill side of the valve have the rework completed.

Distribution pattern: Worldwide distribution: USA (nationwide) and countries of: Brazil, Canada, China, Columbia, Costa Rica, India, Paraguay and Uruguay.

Derived failure modes

  • Unknown

    reason.no_named_rule · v1.0.0

    Isolated incidents of ignition inside Grab n' Go cylinders that had been knocked over or otherwise subject to significant physical impact.

Field note

Send feedback

We'll only use this to respond to your feedback.