Skip to content
Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 88565

1 recalled-product record grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
August 04, 2021
Product types
Device
Classifications
Class II
Statuses
Terminated
Recalling firm wording
Abbott Molecular, Inc.

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

1 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 1

Vysis CLL FISH Probe Kit with the following components: Vysis LSI p53 SpectrumOrange/ATM, SpectrumGreen and LSI D13S319, SpectrumOrange/ 13q34, SpectrumAqua/CEP 12 SpectrumGreen Probes

Z-2576-2021
Recall number
Z-2576-2021
Initiated
August 04, 2021
Classification
Class II
Status
Terminated
Recalling firm
Abbott Molecular, Inc.
Quantity
186 units

App-derived interpretation

Unknown reason.no_named_rule · v1.0.0
Potential for Vysis CLL FISH Probe Kits not detecting 13q deletions in known positive patient samples.

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Unknown

An exact joined enrichment record exists, but none supplies supported root-cause wording. This is not an FDA finding of an unknown cause.

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

Potential for Vysis CLL FISH Probe Kits not detecting 13q deletions in known positive patient samples.

Code information

UDI: (01)00884999042780(10)XXXXX(17)211015(240)04N02-021; US Distribution: Part Number 04N02-021, Lot Numbers 517086, 518656; International Distribution: List/Part Numbers (Lot Number): 04N02-021 (517086, 518656), 04N02-022 (517516, 519303), 05J83-001/Part 32-191025 (517068).

Distribution pattern

Worldwide distribution - US Nationwide distribution in the states of AZ, CA, FL, GA, IL, IN, KY, MI, MN, MA, NC, NJ, NM, NY, OH, PA, TN, TX, UT, VA, VT, WA, WI and the countries of Australia, Belgium, Brazil, Canada, China, Costa Rica, Czech Republic, Estonia, Germany, Hong Kong, Israel, Italy, Kazakhstan, Netherlands, Philippines, Poland, Saudi Arabia, Slovenia, South Africa, South Korea, Spain, United Kingdom, Uruguay.

Field note

Send feedback