Skip to content
Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 83278

1 recalled-product record grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
June 26, 2019
Product types
Device
Classifications
Class II
Statuses
Terminated
Recalling firm wording
Deerfield Imaging, Inc.

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

1 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 1

IMRIS MR/X-ray head fixation device, Model HFD200

Z-0163-2020
Recall number
Z-0163-2020
Initiated
June 26, 2019
Classification
Class II
Status
Terminated
Recalling firm
Deerfield Imaging, Inc.
Quantity
3 units

App-derived interpretation

Unknown reason.no_named_rule · v1.0.0
Breaking of the HFD200 Drive Knob force indicator due to over-torqueing of the drive knob beyond the maximum allowable pinning force specification may result in the clinical staff unknowingly pinning the patient's skull with insufficient force; the clinical staff unknowingly pinning the patient's skull with excessive force; or the clinical staff identifying the issue and not being able to continue with the procedure.

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Device Design

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

Breaking of the HFD200 Drive Knob force indicator due to over-torqueing of the drive knob beyond the maximum allowable pinning force specification may result in the clinical staff unknowingly pinning the patient's skull with insufficient force; the clinical staff unknowingly pinning the patient's skull with excessive force; or the clinical staff identifying the issue and not being able to continue with the procedure.

Code information

HFD Serial Number Drive Knob Serial Number 10002481 10003305 10002351 10005723 10004247 10002448

Distribution pattern

TN, NH, FL

Field note

Send feedback

We'll only use this to respond to your feedback.