Skip to content
Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 79231

1 recalled-product record grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
December 05, 2017
Product types
Device
Classifications
Class II
Statuses
Terminated
Recalling firm wording
Ion Beam Applications S.A.

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

1 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 1

Proteus 235, Uniform and Pencil Beam Scanning The Proton Therapy System - Proteus 235 (brand names: Proteus Plus and Proteus ONE) is a medical device designed to produce and deliver a proton beam for the treatment of patients with localized tumors and other conditions susceptible to treatment by radiation. The PTS may include a fixed small beam treatment room dedicated to the treatment of patients with localized tumors and other conditions susceptible to treatment by radiation localized to the head and neck.

Z-0934-2018
Recall number
Z-0934-2018
Initiated
December 05, 2017
Classification
Class II
Status
Terminated
Quantity
14

App-derived interpretation

Unknown reason.no_named_rule · v1.0.0
An accessory (range shifter, ridge filter&) can be improperly inserted in snout 300x400 with one rail only and the proton therapy system can still operate.

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Device Design

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

An accessory (range shifter, ridge filter&) can be improperly inserted in snout 300x400 with one rail only and the proton therapy system can still operate.

Code information

PAT.000 (US), PAT.003 (KR), PAT.006 (US), PAT.107 (EU), PAT.108 (US), PAT.109 (US), PAT.110 (US), SAT.119 (US).

Distribution pattern

US Distribution to the states of : MA, FL, VA, PA, OK, TN

Field note

Send feedback