Ethicon Endo-Surgery Inc

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

1 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 1

Endopath Electrosurgery Probe Plus II, twelve (12) different devices, including hooks, spatulas, right angles, curved dissectors, suction/irrigation devices, accessory ports, pool/sump devices and stone retrieval cannula, packaged and sterilized individually in a transparent flexible blister sealed to a Tyvek lid. 6 flexible packages are placed into a sales unit carton, with 4 cartons per corrugated shipper. The Endopath Electrosurgery Probe Plus II system has application in minimally invasive procedures to facilitate tissue dissection, coagulation, irrigation, and fluid evacuation through a common trocar sleeve.

Z-1772-2013
Recall number
Z-1772-2013
Initiated
April 08, 2013
Classification
Class II
Status
Terminated
Recalling firm
Ethicon Endo-Surgery Inc
Quantity
327,648 instruments

App-derived interpretation

Unknown reason.no_named_rule · v1.0.0
The firm is recalling the ENDOPATH Probe Plus II Shafts because the possibility that a tear in the Tyvek packaging may affect the sterility of the device.

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Packaging

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

The firm is recalling the ENDOPATH Probe Plus II Shafts because the possibility that a tear in the Tyvek packaging may affect the sterility of the device.

Code information

Product Code: EPS01, Exp. Date: 2015 09 through 2018 03; Product Code: EPS02, Exp. Date: 2015 09 through 2018 03; Product Code: EPS03, Exp. Date: 2015 09 through 2018 03; Product Code: EPS04, Exp. Date: 2015 09 through 2018 03; Product Code: EPS05, Exp. Date: 2015 09 through 2018 03; Product Code: EPS06, Exp. Date: 2015 09 through 2018 03; Product Code: EPS07, Exp. Date: 2015 09 through 2018 03; Product Code: EPS08, Exp. Date: 2015 09 through 2018 03; Product Code: EPS10, Exp. Date: 2013 04 through 2018 03; Product Code: EPS11, Exp. Date: 2013 04 through 2018 03; Product Code: EPS12, Exp. Date: 2013 04 through 2018 03 & Product Code: EPS13, Exp. Date: 2013 04 through 2018 03.

Distribution pattern

Worldwide distribution: US (nationwide) including states of: AK, AL, AR, AZ, CA, CO, CT, FL, GA, lA, ID, IL, IN, KS, KY, LA, MA, MD, ME, Ml, MN, MO, MS, MT, NC, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, & WY and countries of: Canada, Argentina, Australia, Austria, Bahrain, Belgium, Brazil, Canada, Chile, China, Columbia, Czech Republic, Dominican Republic, Ecuador, Egypt, India, Indonesia, Israel, Italy, Jamaica, Japan, Korea, Kuwait, Libya, Malaysia, Mexico, Pakistan, Panama, Philippines, Poland, Puerto Rico, Russia, Singapore, Slovenia, South Africa, Spain, Saudi Arabia, Taiwan, Thailand, Turkey, United Arab Emirates, United Kingdom, Uruguay, & Venezuela.