Skip to content
Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 65348

1 recalled-product record grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
June 04, 2013
Product types
Device
Classifications
Class II
Statuses
Terminated
Recalling firm wording
Invacare Corporation

Dossier provenance

Source snapshots represented here

  • openFDA Device Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.
  • openFDA Device Recall event_date_initiated coverage June 01, 1997–June 30, 2026

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

1 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

device · product 1 of 1

Invacare Power Wheelchair, one per box To provide mobility to a person restricted to a sitting position.

Z-2270-2013
Recall number
Z-2270-2013
Initiated
June 04, 2013
Classification
Class II
Status
Terminated
Recalling firm
Invacare Corporation
Quantity
166,230

App-derived interpretation

Unknown reason.no_named_rule · v1.0.0
Unintended slowing or deceleration, and on rare occasion, unanticipated and unattended acceleration of power wheelchairs equipped with SPJ and MPJ type joysticks.

These labels are deterministic app interpretations, not FDA categories.

Official device-enrichment evidence · Sourced

Process control

Compare all device evidence states

Inspect official wording and provenance

Reason for recall

Unintended slowing or deceleration, and on rare occasion, unanticipated and unattended acceleration of power wheelchairs equipped with SPJ and MPJ type joysticks.

Code information

The following Joystick model numbers and respective part numbers are affected by this recall: CSPJ, 1121239; SPJPLUS, 1127291; SPJAP, 1136937; SPJAPM, 1136938; CMPJM6, 1164361; CMPM6U, 1644361; MPJM6, 1136885; MPJM6U, 1136885; 1558M6, 1136887; 1558MM6, 1136887; 1500M6, 1136889; PACM6, 1136888; PACM6, 1167927; PSRM6, 1139941; PSRM6, 1140046; PSRM6, 1140047; PSRM6, 1140048; PSRM6, 1144844; PSRM6, 1144845; and PSFM6, 1139944. The following Power Wheelchair model numbers (affected date ranges are included in the 1525712 6-3-13 001C model numbers FINAL xlsx document) are affected by this recall: M61UKRD; 3GAR; 3GARBASE; 3GAR-CG; 3GRX; 3GRXBASE; 3GRX-CG; 3GSEAT-CG; 3GSTRX-TS; 3GTQ3; 3GTQ3-CG; 3GTQ3-MCG; 3GTQ3V; 3GTQ-CG; 3GTQ-MCG; 3GTQSE; 3GTQSEBASE; 3GTQSE-CG; 3GTQSE-PTO; 3GTQSP; 3GTQSPBASE; 3GTQSP-TS; FDX; FDX-CG; FDX-MCG; M41BB; M41RB; M41RBCN; M51 PBLUEBASE; M51 PREDBASE; M51BB; M51-CG; M51CGBB; M51CGRB; M51P; M51PBB; M51PBLUEBASE; M51PR; M51PRB; M51PREDBASE; M51RB; M51RBCN; M51SEAT-CG; M61; M61 PBLUE; M61 PRED ; M61 ; KRDBASE; M61(1144227); M61FBLUE; M61FRAD; M61FRED; M61R; M61RB(1144227); M61RBCN; M61RED; M61SEAT; M61UK; M61UK REDBASE; M61UKRD; M61UKRDBASE; M71; M71JR; M71R; M71SEAT; M71-TS; M91; M91-C; M91-M; M91R; M91-R; M91SEAT; M91-TS; M94; M94-C; PTBASE; PTORB; PWORBITS; R51; R51LXP; TDX3; TDX3BASE; TDX3-PS; TDX3SE; TDX3SEBASE; TDX3SE-PS; TDX3SE-TS; TDX3-TS; TDX4; TDX4BASE; TDX4-PS; TDX4-TS; TDX5; TDX5BASE; TDX5-PS; TDX5-TS; TDXSC; TDXSC2-CG; TDXSCSEAT; TDXSCV; TDXSEAT; TDXSI; TDXSI-2; TDXSI-2-S; TDXSI-CG; TDXSI-HD; TDXSI-HD-S; TDXSISEAT; TDXSISEAT-HD; TDXSIV; TDXSIV-2; TDXSIV-2-S; TDXSIV-HD; TDXSIV-HD-S; TDXSP; TDXSPBASE; TDXSP-CG; TDXSP-CG-GT; TDXSP-GT; TDXSP-MCG; TDXSP-MCG-GT; TDXSPREE; TDXSPREE-CG; TDXSPREESEAT; TDXSPSEAT; TDXSR; TDXSR-CG; TDXSR-CG-HD; TDXSR-HD; TDXSR-MCG; TDXSR-MCG-HD; TDXSRSEAT; TDXSRV; and TDXSRV-HD.

Distribution pattern

Worldwide Distribution - USA including AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, and WY. Internationally to Canada, Australia, Bermuda, Brazil, China, Costa Rica, Germany, France, United Kingdom, Guam, Hong Kong, Israel, India, Kuwait, New Zealand, Puerto rico, Qatar, Saudi Arabia, Singapore, Thailand, Trinidad, Tobago, and South Africa.

Field note

Send feedback

We'll only use this to respond to your feedback.