Skip to content
Recall Observatory FDA recall evidence

Exact FDA event identifier

Event 62463

1 recalled-product record grouped only because every row carries this exact official event ID.

Open FDA event record

Event summary

Timeline bucket
July 02, 2012
Product types
Drug
Classifications
Class III
Statuses
Terminated
Recalling firm wording
Hospira Inc.

Dossier provenance

Source snapshots represented here

  • openFDA Drug Enforcement Report-date coverage June 20, 2012–July 08, 2026 Known gap: openFDA describes 2004-present coverage, but the current export has no report-date records in this interval.

Enforcement coverage uses report dates; product initiation dates can precede those bounds. Device-enrichment coverage uses FDA event_date_initiated.

How coverage and grouping work

Complete imported group

Every recalled product in this event

1 official enforcement rows

Product dates, classifications, firms, and source wording remain attached to their individual rows. Opening this dossier never hides products that did not match a prior timeline filter.

drug · product 1 of 1

Carboplatin Injection, 10 mg/mL, a) 5 mL multi-dose vials (NDC 61703-339-18) (NDC 61703-360-18, NOVAPLUS), b) 45 mL multi-dose vials (NDC 61703-339-50) (NDC 61703-360-50 NOVAPLUS), Rx only, Hospira, Inc., Lake Forest, IL 60045, Product of Australia

D-1648-2012
Recall number
D-1648-2012
Initiated
July 02, 2012
Classification
Class III
Status
Terminated
Recalling firm
Hospira Inc.
Quantity
77,542 vials

App-derived interpretation

Potency or specification failure reason.potency_specification_failure · v1.0.0
out of specification

These labels are deterministic app interpretations, not FDA categories.

Inspect official wording and provenance

Reason for recall

Failed PH specification: The lots of Carboplatin Injection were manufactured from Carboplatin API lots which trended out of specification low pH.

Code information

5 mL vial - NDC 61703-339-18 (Hospira label), lot number Y031654AB, expiration APR2013; NDC 61703-360-18 (Novoplus label), lot number Y031654AA, expiration APR2013; 45 mL vial - NDC 61703-339-50 (Hospira label), lot numbers Y041711AA, expiration DEC 2012 and Y061711AB, expiration FEB 2013; NDC 61703-360-50 (Novoplus label), lot number Y061711AA, expiration FEB 2013

Distribution pattern

Nationwide and Puerto Rico

Field note

Send feedback

We'll only use this to respond to your feedback.